USBTracer/Trainer™ 2.15 - Release Notes
Updated: November 29, 2005
1.
Overview
3.1
What’s New
3.2
Known Issues
3.3
API
5.
Support
This Read Me file contains last-minute product information
for the USBTracer ™ software for Microsoft Windows. For full instructions on using the USBTracer/Trainer™ please see
the User's Manual and other documents provided with this product.
The following is a list of recommendations for the configuration
of the host machine that runs the USBTracer™ application and that is connected
to the USBTracer/Trainer™ system. Please note that the application would
operate on systems with less memory and slower CPU rate than the recommended;
however, for best results it is recommended that the host machine meets or
exceeds the suggested configuration.
Operating System:
Microsoft Windows Windows 2000 or Windows
XP.
Required setup:
Microsoft Internet Explorer, version 5 or
newer.
Note:
When Using
Windows XP, please disable the function: "Allow the Computer to turn off
this device to save power." This can be disabled in the My Computer
Properties (System Properties) window under the Hardware Tab. To do so, go to
‘Device Manager’ > ‘Universal Serial Bus Controllers’ > ‘USB Hubs’. Find
the Hub that corresponds to the UPAS 2500H select the Power management tab (The
internal Hub on the CATC Analyzer has 4 ports). If this feature is enabled
(checked), it will cause the UPAS system to hang after a firmware or BusEngine
update. So uncheck it. If you do no want to change this attribute, you can
instead re-enable the port by power cycling your computer.
Processor:
For optimum performance, use processors of Intel's PentiumIII/Pentium4 family, AMD’s Athlon/Duron family, or other compatible processors with clock speed of 500mHz or higher (Processors of Intel’s Pentium II/Celeron family or AMD’s K6 family with clock speed of 300mHz is a minimum).
Memory:
For the best performance, it is recommended to have physical RAM twice the size of the recording buffer setup - 512MB or more (minimum of 128MB of RAM).
Hard Disk:
At least 20MB of free hard disk space is required for the installation. Additional disk space is needed for the operation of the applications and for storing the recorded data in files during the recordings process (can be as much as 500MB when recording a full buffer size).
Display:
Resolution of at least 1024 x 768 with at
least 16-bit color depth is recommended (resolution of 800 × 600 with
16-bit color is a minimum).
Connectivity:
Due to the high-speed uploads, a USB 2.0
interface is recommended for the connection with the USBTracer™ analyzer (USB
1.1 is a minimum). This is not a requirement if the analyzer application is
used only to view pre-recorded traces.
1.
This is
version 2.15 of the USBTracer/Trainer™ product.
2.
This release
contains the following components, which are necessary for the operation of the
product:
o
USBTracer™
Application Version 2.15.
o
USBTracer™ Bus
Engine Version 2.57 (Analyzer + Host Emulation) and Version 2.59 (Analyzer + Device Emulation).
o
USBTracer™
Firmware Version 1.09.
3.
This release
includes the following updates and fixes:
§
Access
Decoding Dialog via "Decode" Button in Toolbar (Always available)
§
Access
Decoding Dialog from ANY packet, transaction, or transfer (You previously had
to look for an appropriate entry!)
§
Single click
selection of decoders (was select then apply)
§
Selection
choices now direction-aware (only applicable ones added to selection list)
o Fixed issue with data toggle and display errors when Control Endpoint is not endpoint 0. (C0006223)
o Trainer: Fixed incorrect display of raw data error. (C0006509)
o
Trainer:
Device emulation generates incorrect packets and corrupts data when in a
loop. (C0006479)
· The integrated Generation File (.utg file) Editor does not work with Windows 98 or Windows ME. You can either edit the .utg files with your own text editor, or upgrade to Windows 2000 or XP.
· Occasionally, uploading may hang on some systems. The I/O times out, and the user must try the trace again. It appears to be a low-level I/O problem, and we are working to resolve it.
· Errors may appear in the last couple of packets of a recording which are not real errors. They are a side effect of the recording terminated during the middle of a packet. Also, the first packet in a trace may be a partial one.
· Installation requires the existence of command.com file, which is not present on a fresh install of Windows 2000.
· In Auto Detect mode, the first few (up to ~20) packets may have errors on a high speed trace due to bouncing of the speed selection relay. These packets should be ignored.
· When uninstalling version 1.60, you may get a dialog asking: "! This will remove InstallShield Dialog Sampler from your computer. Do you wish to proceed?" Just click on "Yes". The correct application WILL be uninstalled. (The phrase in the InstallShield script should have contained the string "USBTracer" in the place of "InstallShield Dialog Sampler".)
OTG
IMPORTANT NOTE REGARDING OTG ADAPTERS:
· For your convenience, we have included 2 USB OTG Adapters for your use in OTG debugging. Included are:
· Suggested OTG Connection Configuration:
o Your OTG "A" DEVICE (with Mini-AB Receptacle)
o Standard-A Receptacle to Mini-A Plug (CATC supplied)
o Standard AB Cable (CATC supplied)
o CATC Analyzer Channel 0 (CATC supplied)
o Standard AB Cable (CATC supplied)
o Mini-AB Receptacle to Standard-A Plug (CATC supplied)
o (Only plug in Mini-A Plugs into this adapter!)
o Mini-A Plug to Mini-B Plug (supplied by you)
o Your OTG "B" DEVICE (with Mini-AB receptacle)
Automation:
·
Sample files Installation: To install the sample
files, please select the ‘Custom’ installation option and select the
‘Automation’ group. The samples are suitable for the USBTracer™ analyzer.
Please refer to the Automation manual for additional information.
· To run the sample files, you should make sure that the USBTracer™ software is already installed.
· The library file name to be used is: USBAutomation.tlb for the USBTracer™ analyzer.
·
HTML Sample:
· For editing the HTML sample code you can use a text editor or other HTML-editing tools.
· CPP sample:
1. To compile the Visual C++ sample project you
first need to install the Microsoft Visual Studio.
2. You can select to install the USBTracer™ software in a directory different
than the default one. If you choose to do so, make sure you add a path to the
installation directory in your project’s paths list. You can find the USBAutomation.tlb file in the installation directory. When
using Microsoft Visual Studio, the path to the installation directory should be
added to the following places in the ‘Project Settings’ property sheet:
(1) Under ‘C/C++’ tab, ‘Preprocessor’ category
in the ‘Additional include directories’.
(2) Under ‘Resources’ tab, in the ‘Additional
resource include directories’.
·
When a remote server is disconnected abruptly while a
client application is still connected, the client application might hang up for
several minutes. At the end of this timeout, the client would be released with
a “The RPC server unavailable” notification. This is due to Windows conduct. [C0004997]
This automation server allows to launch and access CATC analyzer automation servers dynamically at run-time and remotely ( as long as all necessary DCOM settings and permissions are set on the remote server ) and successfully handle automation events from them in situations where otherwise it is difficult or impossible. The examples below will show how limitations imposed by script engines used in HTML browsers and Windows Script Host could be overridden using this adapter server.
Classid :
A0CB5386-38BA-4970-8782-3D1B707C3E5F
ProgID : CATC.AnalyzerAdapter
COM server :
CATCAnalyzerAdapter.exe
Primary default
interface : IAnalazerAdapter
|
HRESULT CreateObject ([in] BSTR class_id, [in,optional] BSTR host_name, out,
retval] IDispatch** ppNewObj ); |
This method instantiates CATC analyzer object on local or
remote machine and attaches it to the adapter
Parameters
class_id -
string representation of classid, or ProgId ( "clsid: 0B179BB3-DC61-11d4-9B71-000102566088"
or "CATC.USBTracer" for CATC USB analyzer )
host_name - the name of the remote server
where the analyzer object should be instantiated. Empty value means localhost.
ppNewObj - pointer to the created remote
object, NULL if the object has not been instantiated or accessed
Return values
Remarks
Only CATC analyzer COM servers can
be instantiated through this method. The method Detach ( see below ) should be
called when the work with the remote object is completed( NOTE: The pointer
returned in ppNewObj should be
released separately ).
Example
VBScript:
</HEAD>
<OBJECT
id=AnalyzerAdapter
classid=clsid:A0CB5386-38BA-4970-8782-3D1B707C3E5F>
</OBJECT>
...
<input
type="button" value="Connect"
name="BtnConnect">
<INPUT
NAME="RemoteServer">
<SCRIPT
LANGUAGE="VBScript">
<!--
Sub
BtnConnect_onclick
On Error Resume Next
Set Analyzer =
AnalyzerAdapter.CreateObject("CATC.USBTracer", RemoteServer.value )
if Not Analyzer Is Nothing Then
window.status = "USBTracer
connected"
else
msg = "Unable to connect to USBTracer"
MsgBox msg, vbCritical
window.status = msg
End If
End
Sub
-->
</SCRIPT>
WSH:
'
Create CATC analyzer adapter first..
Set
AnalyzerAdapter = WScript.CreateObject("CATC.AnalyzerAdapter",
"Analyzer_")
RemoteServer
= "EVEREST"
Set
Analyzer = AnalyzerAdapter.CreateObject("CATC.USBTracer",
RemoteServer)
Analyzer.StartRecording
( Analyzer.ApplicationFolder & "my.rec" )
...
|
HRESULT Attach([in] IDispatch* pObj); |
This method attaches CATC analyzer object to the adapter.
Parameters
pObj -
pointer to the CATC analyzer object to be attached.
Return values
Remarks
Only CATC analyzer COM servers can
be attached to the adapter. If some other analyzer object was previously
attached to the adapter it will be detached by this call. When the analyzer
object gets attached to the adapter a client application using the adapter becomes able to handle automation events
fired by the remote analyzer object through adapter.
Example
VBScript:
</HEAD>
<OBJECT
id=AnalyzerAdapter
classid=clsid:A0CB5386-38BA-4970-8782-3D1B707C3E5F>
</OBJECT>
...
<input
type="button" value="Connect"
name="BtnConnect">
<SCRIPT
LANGUAGE="VBScript">
<!--
Sub
BtnConnect_onclick
On Error Resume Next
Set Analyzer = CreateObject("CATC.USBTracer"
) 'VBScript function creates object
locally
if Not Analyzer Is Nothing Then
AnalyzerAdapter.Attach
Analyzer ' attach analyzer to the adapter
window.status = "USBTracer connected"
else
msg = "Unable to connect to USBTracer"
MsgBox msg, vbCritical
window.status = msg
End If
End
Sub
-->
</SCRIPT>
WSH:
'
Create CATC analyzer adapter first..
Set
AnalyzerAdapter = WScript.CreateObject("CATC.AnalyzerAdapter",
"Analyzer_")
'VBScript
functioncreates object locally
Set
Adapter = WScript.CreateObject("CATC.AnalyzerAdapter")
AnalyzerAdapter.Attach
Analyzer ' Attach analyzer object to the adapter
Analyzer.StartRecording
( Analyzer.ApplicationFolder & "my.rec" )
...
|
HRESULT Detach(); |
This method detaches the CATC analyzer object from the
adapter.
Parameters
Return values
Remarks
This method detaches an analyzer
object from the adapter. This method doesn't guarantee that all resources
associated with the detached object will be freed. All existing pointers to
that object should be released to destroy the remote object.
Example
VBScript:
</HEAD>
<OBJECT
id=AnalyzerAdapter
classid=clsid:A0CB5386-38BA-4970-8782-3D1B707C3E5F>
</OBJECT>
...
<input
type="button" value="Connect" name="BtnConnect">
<input
type="button" value="Disconnect"
name="BtnDisconnect">
<INPUT
NAME="RemoteServer">
<SCRIPT
LANGUAGE="VBScript">
<!--
Sub
BtnConnect_onclick
On Error Resume Next
Set Analyzer =
AnalyzerAdapter.CreateObject("CATC.USBTracer", RemoteServer.value )
if Not Analyzer Is Nothing Then
window.status = "USBTracer connected"
else
msg = "Unable to connect to USBTracer"
MsgBox msg, vbCritical
window.status = msg
End If
End
Sub
Sub
BtnDisconnect_OnClick
AnalyzerAdapter.Detach '
Detach the analyzer object from adapter
Set Analyzer = Nothing ' Release the pointer to the analyzer
returned by CreateOject()
window.status = "USBTracer disconnected"
End
Sub
-->
</SCRIPT>
WSH:
'
Create CATC analyzer adapter first..
Set
AnalyzerAdapter = WScript.CreateObject("CATC.AnalyzerAdapter",
"Analyzer_")
RemoteServer
= "EVEREST"
Set
Analyzer = AnalyzerAdapter.CreateObject("CATC.USBTracer",
RemoteServer)
Analyzer.StartRecording
( Analyzer.ApplicationFolder & "my.rec" )
...
AnalyzerAdapter.Detach ' - Disconnect the remote analyzer from
the adapter
Set
Analyzer = Nothing ' - Release the
analyzer ...
'Release
the adapter ...
Set
AnalyzerAdapter = Nothing
|
HRESULT IsValidObject([in] IDispatch
*pObj, [out,retval] VARIANT_BOOL* pVal ); |
This method helps to determine whether some automation object can be attached to the adapter.
pObj –
pointer to the object validated
pVal
– pointer to the varable
receiving result. TRUE if the validated
object can be attached FALSE otherwise.
Parameters
Return values
Remarks
Only CATC analyzer COM servers
can be attached to the adapter.
Example
VBScript:
</HEAD>
<OBJECT
id=AnalyzerAdapter
classid=clsid:A0CB5386-38BA-4970-8782-3D1B707C3E5F>
</OBJECT>
...
<input
type="button" value="Connect" name="BtnConnect">
<input
type="button" value="Disconnect"
name="BtnDisconnect">
<INPUT
NAME="RemoteServer">
<SCRIPT
LANGUAGE="VBScript">
<!--
Sub
BtnConnect_onclick
'Launch MS Excel instead of USBTracer!!!
Set Analyzer =
CreateObject("Excel.Application")
Analyzer.Visible = True
If Not AnalyzerAdapter.IsValidObject(
Analyzer ) Then
MsgBox "The object cannot be
attached", vbCritical
Set Analyzer = Nothing
Exit
Sub
End If
End
Sub
-->
</SCRIPT>
Bug Fixes:
·
Device
Emulation: Add configurable Device Resume Time
·
Device Emulation:
Fix Looping bugs
·
Device
Emulation: Fix Suspend/Resume functionality
·
Host
Generation: Add device resume capability: add wait_resume=HERE before
resume=nnn statement
·
For extremely
large traces (> 16 million packets), allow for an special option for
decoding files to try to prevent running out of memory while loading the file.
·
Fix bug which
corrupted a trace file during automatic updating from a previous release's file
format.
·
Fix hang when
saving a modified .utg file while NAK's are hidden
New Features:
·
Advanced
Script-Based Decoding
·
Mass Storage
Bulk-Only SCSI Decode
·
Updated Hub
Decoder
·
Update
Bluetooth HCI decoder
·
Added
association of .utg Line Number with Packet on Screen,
·
add ability to
invoke Default Editor
·
Preserve user
overrides on Transfer Types (Interrupt vs. Bulk assignment)
Bug Fixes:
·
Timing
Calculator can now be closed when it's pinned
·
Search for
Frame Number, Empty Frames, and non-empty frames fixed
New Features:
·
Faster Hiding
of Packets
·
Vendor ID's
Decoded into their company name
·
Hide Chirps
button
Bug Fixes:
·
Fix Jitter
problem on some Automatic SOF's generated by USBTrainer
·
Fix problem
where fan could make noise when partially blocked on left side
·
Fix problem which
caused FW to need to be downloaded twice when plug-ins were changed
·
Add a twenty
seconds timeout to prevent infinite hang when I/O failure occurs during
uploading.
New Features:
·
Support for
UPAS 2500H, a USB 2.0 High Speed interface to the host
·
On-The-Go VBus
monitoring (requires version 5 of USBTracer Plug-In)
·
Navigator
Window to help define areas of interest for scrolling within a trace file
·
Dockable
Bandwidth Calculator
·
Descriptor
Decoding window is now sizeable
·
.VCD file
importing function
·
Marker dialog
can remain open while navigating through trace file
·
Add ability to
check syntax on a .utg file without downloading it to the bus engine
·
Search for
Transfer Data Length
·
View Transfer
Data Block
·
Trigger on
Data Length Equals, Less than, Greater than, and Not Equal to a value
·
F1 key-based
Help
·
Explorer
plug-in for previewing .usb files
·
Partial Upload
capability allows efficient conditional use of large traces
·
Generator can
now generate SE0 conditions smaller than 2.5uSec
Bug Fixes:
·
Next and
Previous buttons in Decoding Dialog fixed
·
Fix crash when
hitting Hide Devices button after previously closing it with the close box
(rather than the Apply button)
·
Fix ability to
hide packets based on speed
·
MDATA Packet
Direction fixed
·
Formulas now
shown for Timing Calculator
·
Fix Export
Data bug which exported data from NAK'ed transactions
·
Export Data
now works on transfers over 1 million
·
Fix bug with
recording more than 256 meg when USBTrainer plugged in
·
Fix hang when
hitting Start/Stop button on box when no USBTrainer Plug-In
·
Fix bug which
did not allow DATA2 pids in .utg file
·
Fix decoding
of High Bandwidth Isoch Transfers
·
Fix false
toggle violation when GET Control Transfer returns no data
·
Fix incorrect
identification of Bulk transfer on low speed branch
·
Fix incorrect
toggle violation after Chirp Sequence
·
Fix misc bugs
in Timing Calculator
·
Fix incorrect
explicit frame numbers during export of Hi-Speed traffic to .utg file.
·
Fix bug which
prevented partial nibble mask/match values in data related Recording Resources
(Data Pattern, Transactions, Device Requests)
New Features:
·
Transaction
Decoding in Background allows quicker access to viewing traces
·
Search for
Splits
·
Performance
Enhancements
·
Updating older
files to current versions is now under User's control
·
User can override
transfer types identified for some Interrupt and Bulk transfers, in case
analyzer was not able to distinguish them properly
·
User can
choose Quick Search for Pid's and some Bus Conditions, at the cost of greater
memory use. Also speeds up SOF/NAK
hiding.
·
Quick search
for ANY Errors
·
Add ability to
default to Data Fields Expanded
Bug Fixes:
·
Installation
fixed to avoid possibility of accidental deletion of user's trace files or
other files in the USBTracer directory during uninstall,
·
Fix crash upon
loading previous version files that contain Markers
·
Fix decoding
of OTHER_SPEED_CONFIGURATION descriptor
·
Fix crash when
doing time calculations on Empty trace
·
Fix bug that
prevented USBChief files of release 1.33 from being converted to current
format.
·
Fix bad and or
missing packets when recording on rev 3 or below USBTracer Plug-Ins
·
Improve
Transfer Decoding algorithms to better identify transfer types
·
Fixes to OTG
decoding algorithms
·
Fix bug which
caused Packet Lengths to be reported as 0
·
Fix Auto-Merge
recording options feature
·
Fix incorrect
(bogus) packets which incorrectly show Data Truncation
·
Fix virtual
memory problem in Export to Generator Text feature
·
Fix counters
in Recording Options (only went to 255, now 65535)
·
Fix crash when
double-clicking on a .usb file
New Features:
·
OTG
(On-The-Go) Protocol Support: HNP and SRP decoding and searching
·
Trigger
Sequence Enhancements: Up to 7 levels of trigger event sequencing for ALL event
types. In addition, up to 2 of these
events can utilize Counters.
·
Real-time
Statistics of running traffic (At any time, Tracing or not!)
·
New, more
complete, easier to use Display Options Dialog.
·
Automation
(Remote Control) Interface and API available
·
Up to 512 Mb
Trace with or without USBTrainer module plugged in
·
Search in
Hidden (Search for packets even if they are currently hidden from view)
·
Find All
search function
·
Licensing and
Maintenance infrastructure
·
Split Token
trigger resource
·
Packet
Direction field in Packet View
·
Identify and
report incomplete byte errors
·
Trigger on
incomplete bytes
·
Trigger on
8-bit ext Data Pattern input (Data7-Data0 on Beakout Board)
·
Trigger on
High Speed bus conditions (Chirp, Full Speed J, Full Speed K)
·
Bluetooth
Decoding file is now 1.1 compliant
·
Add search for
FS bus conditions on High Speed Branch
·
Go To Channel
#
·
Go To Host,
HNP, or SRP for On-The-Go traces
·
Windows: Tile
Vertical as well as Horizontal
·
Performance
Enhancements
Bug Fixes:
·
Fix crash when
hitting Device button in Bandwidth Calculator
·
Fix problem
preventing "raw_data=" from working in Generator
·
Channel in
Recording Options dialog not set correctly after saving .rec file
·
Toolbar icons
now correct after an install
·
GP Extern Out
forms not staying set
·
Fix 2.0 GetDescriptors
and SetDescriptors decoding
·
Position
Markers accurately in .utg files
·
Occasional
crash when reading .utg files
·
Merging
Advisor files from USBTracer and vice versa caused crash
·
Fix formats
selection for External Data field
·
Seperate
Intelliframe and Bitstream buttons for Generator
·
Fix crash when
scrolling an empty trace window
·
Fix false
toggle errors after a Bus Reset condition
New Features:
·
Load/Display
.utg Generator files similar to .usb files
·
CHIRP sequence
recording
·
Low Clock
Speed generation and trace capturing for Classic Speed traffic
·
Low Clock
Speed generation and trace capturing for High Speed traffic (Purchaseable
option)
·
Bus
Utilization view
·
Drop-down
display option menus on Packet Fields
·
Trigger on
Data Length
·
8 bits of
External Data Saved (vs 2)
·
Rear panel BNC
Trigger Input supported
·
Markers are
now supported for Transactions
·
Option of
displaying Timestamp in Nanoseconds
·
USBTrainer: NAK/NYET
automatic retry in Intelliframe Mode
·
USBTrainer:
Breakpoints
·
USBTrainer:
Specify # of bits in raw_data packet
Bug Fixes:
·
Fix idle time
calculations when packets are preceded by or follow bus conditions and/or
packets of different speeds (low speed on full speed branch)
·
Fix error in
Suspend Detection
·
Fix error
which caused faulty data to be displayed in the transaction view of a packet
which had errors
·
SplitTransaction
faulty toggle violations fixed
·
Export Data
works on Control Transfers now.
·
Export to Gen
File:
o
Increase
precision of generator idle times
o
Markers cause
syntax error
o
Fix incorrect
suspend times
o
Fix problem
where saving without Naked transactions caused expected_pids to accidentally
disappear
Added Feature:
Classic Speed
Slow Clock Generation. Outputs USB
bitstream at fractions of the standard bit-rate.
Bug Fixes:
·
Fix incorrect
toggle errors on ISOC split transaction
·
Fix problem where
ISOC transactions were being mis-interpreted as BULK transactions, and
vice-versa
·
Fix problem
with doing a SaveAs from Advisor on a USBTracer file (and vice-versa) was
reporting numerous errors incorrectly.
·
Fix bug where
toggle/timeout errors were being reported on addresses that were not on the USB
wire under test.
·
Fix bug which
caused dropped trace data blocks ~30 packets before the end of a trace after
stop button is hit. Generally causes a
false CRC problem,
·
but could be
others. Effects only high speed
traces.
·
Add checking
for ENDPOINT_HALT to reset toggle state of an endpoint. Prior to this, toggle
state was incorrectly shown as being an error in half of the cases.
·
Fix bug which
would cause incorrect data toggle and timeout error analysis on devices with
addresses above 63.
Bug Fixes:
·
Fix Ping
output in Export to Gen File
·
Framing error
in High Speed during reset: was showing errors on 2 packets, should have been
1.
·
Generator:
raw_data=(xx) fixed
·
Use better
filter for transceiver glitches to prevent regular Bad Packets from being
filtered
·
Show missing
NAKs as errors (They were not being shown at any level)
·
Fix various
toggle violation errors: show ones that were being missed, remove false
reports.
·
Fix various
turnaround/timeout violation errors: show ones that were being missed, remove
false reports.
·
Make
turnaround violation visible at Transaction level
·
Add checking
for legal keywords and values in .utg file
·
Fix exporting
Low Speed trace to Gen File
·
Make Timestamps
on consecutive Packets which are the same an Internal Error
·
Fix bug which
caused bad data packets to be generated sometimes when bit stuffing had
occurred.
·
Fix Bus
Conditions timestamp and duration precision.
·
Fix
Suspend/Resume generation problems
·
Fix
tooltip/taskbar interference bug in Windows NT/2K
·
Fixed RESTART
Recording Option Action for Counters and Sequencers.
·
Time Stamp
precision improvements
·
Fix bug in
Suspend and Resume duration calculations.
·
Fix DRAM
Power-on test
·
Fix bad
packets at the beginning of a High Speed trace when in Auto-detect mode
·
Fix erroneous
error packets on full speed during auto-detect.
Updated release of USBTracer. Contains support for USBTrainer.
This is the first release of USBTracer.
Please
periodically check LeCroy Protocol Solutions Group’s web site for software
updates and other support related to this product. Software updates are
available to those users with current Maintenance Agreements.
E-Mail:
mailto:support@catc.com
Voice: +1
800 909 2282 (USA/Canada)
+1 408 727 6600 (worldwide)
Fax: +1
408 727 6622 (worldwide)
E-Mail: mailto:contact.corp@lecroy.com
![]()
© Copyright LeCroy
Corporation 2005
LeCroy, LeCroy Protocol
Solutions Group, USBMobile™, USBMobileHS™, USB Advisor™, USB Chief™, USBTracer™
and USBTrainer™ are trademarks of LeCroy Corporation.
Microsoft Windows is a registered trademark of
Microsoft Inc.
Pentium is a trademark of Intel Corporation.
Athlon and Duron are trademarks of Advanced Micro Devices,
Inc.
Acrobat, Acrobat Reader and the Acrobat logo are
trademarks of Adobe Systems Incorporated.
LeCroy reserves the right to revise these
specifications without notice or penalty.